Tower UPS
  • Tower UPS
  • Tower UPS
  • Tower UPS
  • Tower UPS
  • Tower UPS

Tower UPS

Brand BIOBASE

Product origin CHINA

Delivery time Within 7 days

Supply capacity Factory Direct Supply

Application:
PC, ATM machine, server, network, radio and television, microcomputer room, bank securities network, signal station, mobile base station.

Tower UPS

Feature

● Advanced work mode DSP digital control Technology, high performance.

● Protection of comprehensive and reliable it can effectively solve 9 power problems such as power failure, surge, transient, spike, etc.

● The design of optimizing battery pack 1KVA-24VDC/36VDC(optional), 2KVA-48VDC/72VDC(optional) and 3KVA-72/96VDC(optional).

● Function of the charger extension charging current is 1-4A, support extended to 6A.

● Strong adaptability to environment overload capacity is 120%.

● Intelligent management RS232/USB are optional.

● Overload capacity: 105%-125%, 1mins; load>125%,30s turn to bypass output; load>150%,300ms turn off.

 

Technical Parameter:

Model

BK-U1101B

BK-U1101H

BK-U1102B

BK-U1102H

BK-U1103B

BK-U1103H

Capacity

1000 VA / 800 W

2000 VA / 1600 W

3000 VA / 2400 W

Input

Voltage

110 - 300 VAC (Auto sensing)

Power

Factor

0.99 (nominal output @ full load)

Frequency

46Hz ~55 Hz or 56Hz ~ 64 Hz

Phase

Single phase with ground

Output

Voltage

200/208/220/230/240 VAC

AC Voltage Regulation (Static)

± 1%

Frequency Range

48~ 52 Hz or 58 ~ 62 Hz (Synchronized Range)

50 Hz ± 0.2 Hz or 60Hz ± 0.2 Hz (Batt. Mode)

Current Crest Ratio

3:1

Harmonic Distortion

2 % THD (Linear Load), 6 % THD (Non-linear Load)

Waveform (Batt. Mode)

Pure sinewave

Output Factor

0.8 / 0.9

Transfer Time

AC Mode to Batt. Mode: 0 ms;

AC Mode to Bypass: 4 ms (Typical)

Efficiency (Peak)

AC Mode (@100% RCD load): 88%

Battery Mode (@100% RCD load): 83%

Battery

Type

12V / 9Ah

Battery Numbers

2

External

4

 

External

6

 

External

Typical Recharge Time

5 hours recover to 90% capacity

Charging Current

1A

Charging Voltage

27.4 VDC ± 1%

54.8 VDC ±1%

82.2 VDC ±1%

Indicators

LED / LCD Panel: UPS status, Load level, Battery level, and Fault conditions

Environment

Working humidity: 20-95 % RH @ 0- 40°C (non-condensing);

Noise Level: Less than 50dBA @ 1 Meter

Alarm

Battery Mode: Sounding every 4 seconds

Low Battery: Sounding every second

Overload: Sounding twice every second

Fault: Continously sounding

Optional SNMP

Communication: RS232 Card / Optional USB Card, SNMP Card, or AS400 Card available; Supports Windows2 2000/2003/XP/Vista/2008, Windows2 7, Linux, Unix, and MAC.

Optional SNMP: Power management from SNMP manager and web browser.

External Size(W*D*H) mm

145*350*228

145*350*228

190*395*328

190*395*328

190*395*328

190*395*328

Package Size(W*D*H) mm

236*428*333

236*428*333

325*493*458

325*493*458

325*493*458

325*493*458

Net weight (kg)

9.6

4.9

17.5

8.3

23

8.9

Gross weight (kg)

10.7

6.2

19.1

9.6

25

10.3

* If the UPS is installed or used in a place where the altitude is above than 1000m, the output power must be derated one percent per 100m.

* When the temperature is lower than 30°C, the power factor can be adjusted to 0.9.