Ion Chromatograph
Brand BIOBASE
Product origin CHINA
Delivery time Within 7 days
Supply capacity Factory Direct Supply
Introduction:
The ion chromatograph not only can detect anions, cations and other polar substances in different matrix samples, but also separate ions with four orders of magnitude difference. Intelligent maintenance function is added to give users a better experience. It is suitable for third-party testing institutions, enterprises, environmental protection, chemical industry, mining and metallurgy and other fields.
Feature:
1.Built-in circulating 3D constant temperature technology
Temperature stability time is less than 30 mins, ensuring the accuracy and reliability of test data.
2.The world's leading full-range series of ion chromatographic columns
High efficiency, large capacity of the columns for detecting ions of varied compositions.
3. Self-Regenerating Electrolytic Micro-membrane Suppressor
High pressure resistance, small dead volume, highly responsive to signals.
4. Auto-range Conductivity Detector
It can directly detect the signal from ppb to ppm without adjusting the range; Only one conductivity detector can detect anions and cations.
5. Observatory intelligent workstation
Integrated control; With intelligent start-up, shutdown and maintenance functions; Compatible with a variety of instruments; Customized images.
Technical Parameter:
Model | BK-IC100 | |
IC Pump
|
Type | High-pressure and low-pulse two-piston tandem advection pump |
Maximum Pressure |
35 MPa (PEEK) | |
Pressure Display Accuracy |
≤0.1MPa | |
Flow Stability | (0.2-0.5) mL/min≤3%; (0.5-1.0) mL/min≤2%; >1.0mL/min≤2%; | |
Allowable Deviation of Flow | (0.2-0.5) mL/min , ±5%; (0.5-1.0) mL/min, ±3%; >1.0mL/min, ±2%; | |
Flow Range | 0.001~9.999mL/min | |
Pressure Pulse | ≤0.5% | |
Flow Precision | ≤0.1% | |
Flow Accuracy | ≤0.1% | |
Manual Sample Injector | Maximum Pressure | 35MPa |
External Diameter of the Tube | 1/16" | |
Contact Material of the Rotor | PEEK | |
Contact Material of Medium | PEEK/Ceramics | |
Column Heater
| Operating Temperature Range | 20~60℃ (68~140℉) |
Controlling Temperature Accuracy | ±0.01℃ | |
Allowable Deviation of Column Heater’s Temperature | ±1℃ | |
Temperature Stability | ≤0.05℃/h | |
Conduction Detection System
| Type | Constant temperature auto-range conductivity detector |
Cell Volume
| ≤0.8μL | |
Detection Range | 0~35000μS/cm | |
Detection Resolution | ≤0.0020nS/cm | |
Output Voltage | -6000~+6000mv(adjustable) | |
Electronic Noise | 0.02nS | |
Baseline Noise | ≤0.001μS/cm | |
Baseline Drift | ≤0.02μS | |
Operating Temperature Range | Room temperature +5℃~60℃ (41 ~140℉) | |
Controlling Temperature Accuracy | ±0.01℃ | |
Temperature Compensation | 1.7 %/℃ | |
Maximum Pressure | 10.0MPa | |
Linear Range | ≥103 | |
Instrument Linearity | ≥0.999 | |
Quantitative Repeatability | ≤1.0% | |
Qualitative Repeatability | ≤0.5% | |
Minimum Detectable Concentration | Cl-≤0.0005ug/mL; Li+≤0.001ug/mL; BrO3-≤0.001ug/mL; | |
Flow System
| Plastic Flow Path | Made of PEEK materials |
Six-way Valve | PEEK material, pressure 5000psi; Independent automatic collecting and flow function. | |
Suppressor | Type | Self-Regenerating electrolytic micro-membrane suppressor |
Maximum Pressure | 6.0MPa | |
Dead Volume | <50μL | |
Power Supply | 220V 50/60Hz(Standard);110V 50/60Hz (Optional);150W | |
External Size(L*W*H*) | 325*400*500mm | |
Net Weight | 21kg |