Immune Blood Centrifuge
Brand BIOBASE
Product origin CHINA
Delivery time Within 7 days
Supply capacity Factory Direct Supply
Model BKC-TL4Ce
Introduction:
BKC-TL4Ce can be used for lymphocyte washing in HLA examination, erythrocyte washing in freezing test, etc. lt is aspecial centrifuge developed for experiments such as erythrocyte washing and immunologica detection.
Download
Features:
1. SERO rotor and HLA rotor centrifuge procedures are standardized and can be easily invoked.
2. With special red blood cells to clean SERO rotors, lymph cells to clean HLA rotors, easy to install.
3. The rotor sleeve contains a clamp, which is convenient for the test tube to ft tightly with the rotor, and the centrifugal effect is better.
4. Can store multiple groups of user-defined programs, easy to call common programs, boot for the last program.
5. Food-grade silicone integral sealing ring to avoid aerosol spill and ensure the safety of staff.
6. Alarm detection function, real-time detection of door lock and motor status, safe and reliable operation.
7. Microcomputer control, DC brushless motor drive, large torque, no toner pollution, maintenance-free.
8. Multi-stage centrifugation/conventional centrifugation mode, can be switched at will; Can be set up 5 stage muli-stage centrifugation, to meet a variety of needs.
9. There are more than 30 user-defined program groups for separating and cleaning lymphocytes for HLA tests, all in one machine.
Technical Parameters:
Model | BKC-TL4Ce |
Max.Speed | 4040rpm |
Max.RCF | 2147×g |
Max.Capacity | 12*15ml |
Speed Precision | ±10rpm (±1%) |
Timing Range | 1s~99min |
Noise | ≤62dB |
Consumption | 150W |
Power Supply | AC110V/220V, 50/60Hz |
External Size (L*W*H) | 340*430*278mm |
Package Size (L*W*H) | 456*546*456mm |
Net Weight | 20kg |
Gross Weight | 24kg |
Rotors Type | Capacity | Program group | Max.Speed | Max.RCF | Centrifugal time | Use |
Lymphocyte | 12*(0.2~1.5)ml | E | 4040rpm | 2000×g | 180s | Lymphocyte isolation, culture |
F | 2860rpm | 1000×g | 3s | Removal of platelets | ||
G | 2860rpm | 1000×g | 60s | The cleaning of lymphocytes | ||
Red Blood | 12*7/5ml | H | 2120rpm | 500×g | 60s | Blood group determination, hem agglutination reaction observation |
I | 3000rpm | 1000×g | 15s | Cross fit test, anti globulin test | ||
J | 3000rpm | 1000×g | 60s | Blood cell cleaning, serum and plasma extraction | ||
Angle Rotor | 12*10ml | / | 4000rpm | 2147×g | / | 1.5ml, 2/3/4mlvacuum blood collection tube |
Note:The default is round-bottom tube,with mark(△)is sharp-bottom tube